- Device drivers
- 3.4.28
- 2.7.34
- 2.6.14
- 2.5.19
- 2.4.07
- 2.3.07
USB 2.0 fullspeed Mini USB connector Standard USB connector PCI Rev 2.2 Vehicle interface: Suitable for 12V systems Suitable for 24V systems Physical Layer: K/L-Line ISO 9141(-2) 1: 1: 1: CAN 2.0B high-speed: 1: 2: 2: CAN low-speed 1: 1: 1 3: LIN 4: 1: Vehicle connection: D-SUB connector. (7) Check “Control Panel/Devices Manager/Softing”. If it’s not installed correctly, update the device driver manually. (8) Make a shortcut of “EDICConfig.exe” on Desktop. (9) (option) If you have newer version than EDICPDUAPI 12042 driver and genuine VAS5054A hardware, you may install the API driver now. Post Installation.
Device drivers
IXXAT USB-to-CAN V2 compact
From April 14th, 2014, IXXAT started the delivery of the latest USB-to-CAN V2 interface generation which replaces the old USB-to-CAN interfaces (see more here). To be able to use the new IXXAT device with ST03A versions from V3.3.45 and higher please replace the IXXAT driver installed from the ST03A CD with the VCI V3.5.2.4072 as described below. For ST03A versions lower than V3.3.45 please first upgrade your Service Terminal version to the newest one to be able to use the new IXXAT USB-to-CAN V2 compact. |
Warning: IXXAT and Windows 10 with Secure Boot
The IXXAT VCI 3 driver must not be installed on computers that use Windows 10 with Secure Boot enabled. For computers with activated Secure Boot please use ST03A V3.9 or above with IXXAT VCI 4 driver.
To replace the old IXXAT driver with the new IXXAT VCI 3.5.2.4072 device driver to work properly with ST03A:
- Uninstall the 3.4 version of IXXAT VCI driver.
- Start
vci_3_5_2_4072.exe
to install the IXXAT VCI 3.5.2 device driver (see more here). - Connect the USB-to-CAN V2 compact adapter to the USB port and follow the appearing instructions.
- Start ST03A.
- Select the Tools > Options.. menu item.
- Choose the Devices node on the left side of the window.
- Select IXXAT in the drop down list.
- Click OK to close the Options dialog window.
The following IXXAT devices and drivers can be used with ST03A versions:
Supported device driver versions | ST03A V2.4.07, V2.5.19, V2.6.14 | ST03A V2.7.34, V3.0.72, V3.1.24, V3.2.13 | ST03A V3.3.45, V3.4.31, V3.5.45, V3.6.43, V3.7.32, V3.8.01 | ST03A V3.9.00, V3.9.01, V3.9.02, V3.10.00 |
---|---|---|---|---|
IXXAT USB-to-CAN V2 (new) | (not supported) | (not supported) | 3.5.2 | 4.0.598.0 |
Softing CANpro USB
Drivers Installer for StenoCast USB Serial Converter A. If you don’t want to waste time on hunting after the needed driver for your PC, feel free to use a dedicated self-acting installer. It will select only qualified and updated drivers for all hardware parts all alone. To download SCI Drivers Installer, follow this link. Serial/Parallel Port. Download Driver: Windows XP (64 bit) StenoCast: 2.08.02 (7/12/2010). Computer's installed devices, identify the best fitting drivers. Stenocast port devices driver download.
Softing Ag - Germany USB Devices Driver
From 2014, Softing started the delivery of the latest CANpro USB interface generation which replaces the old CANusb interfaces (see more here). To be able to use the new Softing device with ST03A versions from V3.5.45 and higher please replace the Softing driver installed from the ST03A CD with the CAN Driver V5.17 as described below. For ST03A versions lower than V3.5.45 please first upgrade your Service Terminal version to the newest one to be able to use the new Softing CANpro USB. |
To replace the old Softing driver with the new Softing CAN V5.17 device driver to work properly with ST03A:
- Uninstall previous versions of Softing CANusb driver.
- Download
ST03AV3.6.43_drivers.zip
, unzip and startCANDriversAndSoftware.exe
to install the device driver (default settings can be applied). - Connect the CANusb adapter to the USB port and follow the appearing instructions.
- Start ST03A.
- Select the Tools > Options.. menu item.
- Choose the Devices node on the left side of the window.
- Select Softing CANusb in the drop down list.
- Click OK to close the Options dialog window.
The following Softing devices and drivers can be used with ST03A versions:
Supported device driver versions | ST03A V2.4.07, V2.5.19, V2.6.14, V2.7.34, V3.0.72, V3.1.24, V3.2.13 | ST03A V3.3.45, V3.4.31 | ST03A V3.5.45 | ST03A V3.6.43, V3.7.14, V3.7.18 | ST03A V3.7.31, V3.8.01 | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|